Epe Nota Parkeernormen 2024 – Municipal Parking Standards and Requirements
The Nota Parkeernormen 2024 is the official regulatory framework issued by the Gemeente Epe, Netherlands, to determine the required number of parking spaces for new construction projects and changes in building use. Effective from October 1, 2024, this municipal ordinance ensures that parking demand is met within the project area to prevent excessive parking pressure on public spaces. It operates under the wider legal framework of the Omgevingswet and aligns with national guidelines from the CROW (Publication 381: Toekomstbestendig parkeren).
The document governs parking requirements for both motor vehicles and bicycles across various domains, including residential housing, commercial workplaces, retail, health services, and education. It defines specific zoning classifications based on urbanization degrees, distinguishing between Centrum Epe, Centrum Vaassen, the Rest bebouwde kom (remaining built-up area), and the Buitengebied (outlying area). For parking garages, technical standards from NEN 2443 are applicable.
Professional users can utilize the structured four-step process detailed in this document to calculate the total parking requirement. This includes determining the area category, establishing the spatial program, applying attendance percentages for dubbelgebruik (dual use), and final calculation of the parking demand. The document also provides specific criteria for deviations, financial contributions to the municipal parking fund, and safety regulations for electric vehicle charging in underground facilities.
Calculation Methodology for Parking Demand
The determination of the parking requirement follows a specific four-step procedure designed to tailor requirements to the location and intended use of the development:
- Step 1: Area Classification: Identifying if the project falls within Centrum Epe, Centrum Vaassen, the rest of the built-up area, or the outlying area.
- Step 2: Spatial Program: Calculating the parking demand per function based on surface area (m2 BVO) or number of housing units.
- Step 3: Dual Use (Dubbelgebruik): Assessing if parking spaces can be shared between different functions based on peak demand times (e.g., retail peaks on Saturday vs. office peaks on weekdays).
- Step 4: Total Requirement: Determining the final demand based on the time of day with the highest cumulative occupancy.
Residential Parking Standards
Parking norms for residential developments are differentiated by housing type, size, and price segment. For every dwelling, a minimum visitor parking component of 0.3 spaces must be provided and remain publicly accessible.
- Landed Houses (Grondgebonden): Norms vary by floor area; for example, a home >150 m2 in the Buitengebied requires 2.4 spaces, while the same size in Centrum Epe requires 1.8 spaces.
- Non-Landed Housing (Niet-grondgebonden): Apartment requirements are categorized by social rent, private sector rent, and owner-occupied segments.
- Private Driveways: The document applies a reduction factor for parking on private property to account for actual usage patterns (e.g., a single driveway counts as 0.8 spaces toward the requirement).
Acceptable Walking Distances
Parking spaces must be realized within a specific radius of the main function. The following maximum walking distances are defined as acceptable:
- Residential (Wonen): 100 meters.
- Retail (Winkelen): 200 to 600 meters.
- Workplace (Werken): 200 to 800 meters.
- Health and Education: 100 meters.
Deviations and the Municipal Parking Fund
The College van burgemeester en wethouders may grant an exemption from the parking requirement if realization on-site is impossible or undesirable. This involves a hierarchical assessment:
- Local Capacity: Utilization of existing public parking spaces if occupancy remains below 70% during peak hours.
- Financial Settlement: If on-site and local solutions fail, the developer may pay a contribution of €8,900 per parking space into the municipal parking fund.
- Exceptional Social Value: Exemptions may be granted for projects providing exceptional social or spatial quality even if parking norms are not fully met.
Frequently Asked Questions
What is the car ownership rate in Epe used for these norms?
The car ownership rate in Epe was measured at 1.2 per household in 2020, which is higher than the national average of 0.9.
How are parking space numbers rounded in calculations?
Calculations are precise to one decimal point, and the final result is rounded to the nearest whole number, where 0.5 and higher is rounded up.
What are the rules for charging electric vehicles in underground garages?
EV charging in public underground garages is permitted only under strict conditions due to fire safety risks, following advice from the VNOG fire department.
What is the minimum width for a disabled parking space?
Publicly accessible parking spaces for the disabled must have a minimum width of 3.50 meters.
How many bicycle parking spots are required for a standard apartment?
An apartment with a bicycle storage room has a norm of 0.75 spots per room, with a minimum of 2 spots per apartment.
When can double use (dubbelgebruik) be applied to a parking plan?
Double use can be applied when a project contains multiple functions with different peak demand times, using the attendance percentages found in Table 3 of the document.