Nota Parkeernormen 2021 – Parking Standards for Pijnacker-Nootdorp
The Nota Parkeernormen 2021 is the official regulatory framework issued by the municipality of Pijnacker-Nootdorp to determine the required number of parking spaces for spatial developments. Adopted by the municipal council on February 24, 2022, this document serves as a technical update to the previous 2012 and 2015 versions. It is based on the national guidelines provided by CROW (Toekomstbestendig parkeren - Kencijfers parkeren en verkeersgeneratie, 2018) and operates within the legal context of the Inspraakverordening 2006 and the Algemene wet bestuursrecht.
The scope of these regulations covers all new construction, infill development, expansions, and changes of use for buildings or sites within the municipal boundaries. The municipality is classified under the rest bebouwde kom (rest of the built-up area) category due to its high car ownership rates and specific urban density. The document outlines specific calculation methods for private parking facilities, minimum physical dimensions for parking spaces, and a detailed list of parking requirements categorized by land use functions such as residential, commercial, retail, and healthcare.
The following sections detail the technical application of these standards, including specific requirements for shared use and the procedural steps for assessing parking demand in large-scale and small-scale developments.
Calculation Standards for Private Parking
When parking is provided on private property, the municipal standards apply specific calculation factors to determine the effective capacity. These factors account for the reality that private garages or driveways are not always used for parking vehicles.
- Single driveway without garage/carport: 0.8 spaces.
- Single driveway with garage/carport: 1.0 space.
- Double driveway with garage/carport: 1.8 spaces.
- Garage/carport without driveway (non-residential): 0.5 spaces.
- Collective parking garage/lot (residential complex): 1.0 space per actual spot.
Minimum Dimensions and Technical Requirements
The document specifies minimum dimensions for various parking facilities to ensure functional accessibility. If a driveway serves as the sole access to a front door or bicycle storage, the required width increases by 0.80 meters.
- Single driveway: Minimum length of 6.00 meters and width of 2.50 meters.
- Long driveway: Minimum length of 10.00 meters and width of 2.50 meters.
- Double driveway: Minimum length of 6.00 meters and width of 4.50 meters.
- Parallel parking space: 5.50 meters long by 2.00 meters wide (increased to 6.00 meters length if not adjacent to another space).
- Disabled parking (parallel): 3.50 meters by 7.50 meters.
Parking Standards by Function
Parking requirements are determined based on the specific function of the property. For residential developments, the norm includes a mandatory visitor component, typically set at 0.3 spaces per unit.
- Detached house (owner-occupied): 2.2 spaces per dwelling (including 0.3 for visitors).
- Social housing (rental): 1.2 spaces per dwelling (including 0.3 for visitors).
- Office (without counter function): 2.05 spaces per 100 m² GFA (gross floor area).
- Full-service supermarket (1000-2000 m²): 5.2 spaces per 100 m² sfa (sales floor area).
- Sports hall: 2.85 spaces per 100 m² GFA.
Dual Use and Presence Percentages
To optimize land use, the municipality allows for the shared use of parking spaces between different functions that have peak demands at different times. The Table 4 Aanwezigheidspercentages (Presence Percentages) provides the basis for these calculations.
- Residential (residents): 100% presence during work nights, 50% during work mornings.
- Offices: 100% presence during work mornings and afternoons, 5% during work nights.
- Retail: 100% presence on Saturday afternoons, 0% during work nights.
Frequently Asked Questions
What is the parking requirement for a social housing unit in Pijnacker-Nootdorp?
The standard is 1.2 spaces per dwelling, which includes a 0.3 visitor component. Small dwellings under 65m² GFA also use this 1.2 norm.
How wide must a single driveway be according to the 2021 standards?
A single driveway must be at least 2.50 meters wide, but this increases to 3.30 meters if it is the only access to the front door or bicycle storage.
What rounding rules apply to parking demand calculations?
Calculations are generally rounded up to the nearest whole number (e.g., 15.1 becomes 16), except for single private homes with a double driveway and garage, which may be rounded down.
Does the municipality allow for shared parking between offices and residents?
Yes, shared use is calculated using presence percentages; offices peak during workdays (100%), while residents have lower presence (50%), allowing for shared capacity.
What happens if a project cannot meet the parking standards on-site?
If the norm cannot be met on-site and the hardheidsclausule (hardship clause) does not apply, the college may refuse the permit or request a substantiated deviation to be submitted to the council.
What is the parking norm for a general practitioner's office?
The norm is 2.85 spaces per treatment room, which includes a visitor share of 0.57.