Bygningsreglementets vejledning om tilgængelighed ved transportable konstruktioner – Accessibility Guidance for Temporary Structures
The Bygningsreglementets vejledning om tilgængelighed ved transportable konstruktioner is the official guidance issued by the Trafik-, Bygge- og Boligstyrelsen (Danish Transport, Construction and Housing Authority). Published as the first edition on September 3, 2020, this document is directly linked to the Danish Building Regulations BR18. It establishes the specific requirements for ensuring that temporary and transportable structures erected for public access are accessible to all citizens, including wheelchair users and individuals with reduced mobility or sensory impairments.
The regulatory scope covers a wide range of temporary installations such as boder (stalls), telte (tents), and tribuner (stands) used at marketplaces, festivals, and outdoor events. The guidance details how the general accessibility provisions found in Bygningsreglementets kapitel 2, §§ 48-53 apply to these specific contexts. It provides technical specifications for access paths, floor surfaces, lighting, door widths, and the management of physical obstacles such as cables and structural supports. The document also references international standards including DS/ISO 21542 and DS-håndbog 186 for additional technical inspiration.
The following sections detail the mandatory and recommended technical solutions for achieving compliance during the planning and assembly of transportable structures in Denmark.
General Accessibility Requirements
Access conditions for transportable structures must be designed so that users can reach and enter the facilities independently. This aligns with the requirements set out in Bygningsreglementets kapitel 2, §§ 48-53.
- Independent access: Users must be able to navigate to and into the structure without assistance.
- Universal design: Requirements apply to wheelchair users, those using walkers (rollator), and people with orientation difficulties.
- Service areas: Horizontal areas must be provided outside entrances and service functions, such as food and beverage outlets, to allow for maneuvering space.
Access Paths and Surfaces
The guidance recommends establishing dedicated access paths that are visually distinct from the surrounding terrain. These paths ensure direct guidance to entrances and activities.
- Surfacing: Paths should have a firm, slip-resistant covering.
- Lighting: For activities occurring after dark, paths must be equipped with non-glare, directional lighting.
- Ramps: The use of loose or temporary ramps is discouraged as they are often perceived as unsafe by wheelchair users.
Doorways and Passages
Specific dimensional requirements apply to all doors and passages within the transportable construction to ensure sufficient clearance for mobility aids.
- Free passage width: Every door or passage must maintain a minimum clear width of 77 cm.
- Maneuvering space: Sufficient space must be allocated beside doors to allow them to be opened by a person in a wheelchair.
- Level thresholds: Where construction or terrain conditions require it, landings and levelings must be established both inside and outside the entrance.
Management of Cables and Obstacles
Surface-mounted technical installations such as cables that cross access paths must be addressed to prevent them from becoming barriers.
- Height threshold: Protection or leveling is required if cables are higher than 2.5 cm.
- Wedge slopes: For cable crossings up to 15 cm high, the wedge slope must not exceed 10% (1:10). For heights exceeding 15 cm, the slope must not exceed 5% (1:20).
- Passage width: Cable crossing points must provide a minimum passage width of 130 cm.
- Hazard marking: Guy ropes (barduner), large stakes, and structural supports must be marked with a minimum 5 cm wide contrasting tape or tactile markers.
Frequently Asked Questions
What is the minimum door width for transportable structures in Denmark?
All door passages and doors in transportable constructions must have a minimum free passage width of 77 cm.
How should cables crossing access paths be managed?
Cables higher than 2.5 cm must be either recessed into the surface or covered with wedges that have a maximum slope of 10% for heights up to 15 cm, or 5% for heights above 15 cm.
Are loose ramps permitted for accessibility?
The guidance advises against the use of loose ramps as they are frequently experienced as unstable or unsafe by wheelchair users.
What are the lighting requirements for temporary access paths?
If activities take place after dark, access paths should be provided with good directional and non-glare lighting to assist users with orientation.
How wide must a cable crossing passage be?
The width of the passage where users cross over cables must be at least 130 cm to accommodate walkers and wheelchairs.
How should guy ropes and stakes be marked for safety?
Structural supports like guy ropes or stakes must be marked with a contrasting color band at least 5 cm wide or via tactile/visible markers in the paving.